ADLINK Technology cPCI-9116 Guia do Utilizador Página 42

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 67
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 41
32 Registers
EOC_en (bit8): End of conversion Interrupt Enable Control
1: Enable
0: Disable
Clr_Timer (bit4): write 1 to clear the GPTC Interrupt status
1: clear interrupt from the GPTC
0: no effect
Clr_SCTC (bit3): write 1 to clear the SCTC Interrupt
1: clear the interrupt on terminal count of the Scan
counter
0: no effect
Clr_HFull (bit2): write 1 to clear the data FIFO half full interrupt
1: clear the interrupt on the data FIFO half full status
0: no effect
Clr_DTrg (bit1): write 1 to clear the Digital Trigger Interrupt
1: clear the interrupt when trigger happens
0: no effect
Clr_EOC (bit0): write 1 to clear the End of Conversion Interrupt
1: clear the interrupt when EOC
0: no effect